Error message - Error: U00000009 '': Access denied when selecting the variable picker for Archive Key 1, 2 or Internal Account on the General Page of an object.
book
Article ID: 132410
calendar_today
Updated On:
Products
CA Automic Workload Automation - Automation Engine
Issue/Introduction
When selecting the variable picker for Archive Key 1, 2 or Internal Account on the General Page of an object the following error message is generated:
Error: U00000009 '': Access deniedÂ
Cause
An internal call is incorrectly referencing the AH table instead of the OH table.
Environment
Release: Component: AAUTEN
Resolution
The issue was found and fixed with:
Automation.Engine 12.1.5 in UserInterface Web released 05-20-2019 Automation.Engine 12.2.3 in UserInterface Web pending release.
Hotfix-Description: Variable picker for Archive Key 1, 2 or Internal Account on the General Page did not work properly raised an "Access Denied" error.