Can CA 11 run on multiple LPARs in a Sysplex and share the Datacom/AD Muf
search cancel

Can CA 11 run on multiple LPARs in a Sysplex and share the Datacom/AD Muf

book

Article ID: 132295

calendar_today

Updated On:

Products

CA-11

Issue/Introduction



Can CA 11 run on multiple LPARs in a Sysplex and share the Datacom/AD Muf?

Environment

Release:
Component: 11

Resolution

In a sysplex environment, you can have a CA 11 running on each LPAR.  Each of the CA 11's will use the same  Datacom/AD Muf.
The CA 11 on the same LPAR as Datacom/AD Muf will access it via the SVC.  The CA 11's on the other LPARs in the sysplex will
access the Datacom/AD Muf via XCF.  Only one CA 11 will run the MAINT task and that would be the one  residing on the same LPAR 
as the Datacom AD/Muf.   The config file for that CA 11 will have MAINTTME set to a non zero value while the config file used by the
other CA 11's have  MAINTME=0 specified.   