Can CA 11 run on multiple LPARs in a Sysplex and share the Datacom/AD Muf
book
Article ID: 132295
calendar_today
Updated On:
Products
CA-11
Issue/Introduction
Can CA 11 run on multiple LPARs in a Sysplex and share the Datacom/AD Muf?
Environment
Release: Component: 11
Resolution
In a sysplex environment, you can have a CA 11 running on each LPAR. Each of the CA 11's will use the same Datacom/AD Muf. The CA 11 on the same LPAR as Datacom/AD Muf will access it via the SVC. The CA 11's on the other LPARs in the sysplex will access the Datacom/AD Muf via XCF. Only one CA 11 will run the MAINT task and that would be the one residing on the same LPAR as the Datacom AD/Muf. The config file for that CA 11 will have MAINTTME set to a non zero value while the config file used by the other CA 11's have MAINTME=0 specified.
As always, please contact Broadcom support for Workload Automation Restart Option for z/OS Schedulers if you have further questions.