DUAS6: Uproc with conditions sizeunchanged - "Invalid operation code"
search cancel

DUAS6: Uproc with conditions sizeunchanged - "Invalid operation code"

book

Article ID: 132159

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Following an upgrade or import of Uprocs from a Dollar Universe version 5 node containing "SIZEUNCHANGED" conditions on a node in version 6, those Uprocs remain in status Event Wait / Time Overrun, even though the condition is satisfied.
When checking the "uxshw upr" output, we observe that the parameter oper (operator) has the value  ">" instead of "=>" 

 The following errors appear in universe.log once the Job is launched and EEP verifies the resource: 

|ERROR|X|EEP|pid=p.t| o_eep_check_file_sizeunch | Invalid operation code 
|ERROR|X|EEP|pid=p.t| o_eep_check_file_resource | Error checking the condition: file_check_fnc returns -1 

 

Environment

Dollar Universe 6

Cause

Unnecessary Control on operator code (<, >, <= , = ...) as it is not used for conditions sizeunchanged and dateunchanged.

Resolution

Workaround:
Recreate the impacted SIZEUNCHANGED Condition via the command line or via Univiewer Console 6.x

Solution:
Update to a fix version listed below or a newer version if available.

Fix version(s): 
Component: Application.Server
Dollar Universe 6.10.01 - Released 30th May 2019