After an IPL the IMS CTL region experiences messages ETM4007W and ETM4008I followed by an abend.
search cancel

After an IPL the IMS CTL region experiences messages ETM4007W and ETM4008I followed by an abend.

book

Article ID: 131968

calendar_today

Updated On:

Products

Database Analyzer (IMS Tools) Mainframe Configuration Manager for IMS for z/OS IMS TOOLS - MISC Compress Data Compression (IMS Tools) Database Analyzer for IMS for z/OS Database Copier for IMS for z/OS Database Organizer for IMS for z/OS Mainframe Extended Terminal Manager (IMS Tools) High Performance Recovery for IMS for z/OS Database Organizer (IMS Tools) Mainframe Program Restart Manager for IMS for z/OS Secondary Index Builder for IMS for z/OS Secondary Index for IMS for z/OS

Issue/Introduction

After an IPL, the IMS Control Region (CTL) may experience the following messages at start up, followed by an abend:

ETM4007W EXTENDED TERMINAL MANAGER FAILED LICENSE VALIDATION. 
ETM4008I PLEASE ENSURE THE LICENSE INFORMATION IS CORREECT. 

Followed by either

DFS629I IMS CTL TCB ABEND - SYS 0C4 
or
DFS629I IMS CTL TCB ABEND - SYS 122

The abend is reported in module ID ETMINTXZ.
 

Environment

Release:
Component: ETM

Cause

The abend is occurring in license checking for CA Mainframe Extended Terminal Manager for IMS (ETM) and can occur when CAIRIM either has not been started, or when it has not completed initialization. 

This could be a timing issue after the IPL. It could be that the IMS control region is being started too soon before CAIRIM has completed initialization. 
 

Resolution

Check that CAIRIM has been started successfully. CAIRIM would normally be started automatically as a started task after the IPL. The start command for this is 'S CAS9'.

You can run CAIRIM multiple times as it tracks products that are installed correctly and bypasses the initialization of those products that are already running. 

Once CAIRIM has been completed successfully then the IMS Control Region can be started.