Sysview for DB2's post-install IDB2SYS process encounters: WRNG.LEN.RECORD ON PROFILE DATASET
book
Article ID: 131869
calendar_today
Updated On:
Products
Bind Analyzer for DB2 for z/OSSQL-Ease for DB2 for z/OSSYSVIEW Performance Management Option for DB2 for z/OSPlan Analyzer for DB2 for z/OSSubsystem Analyzer for DB2 for z/OS
Issue/Introduction
Performing an upgrade from CA DB2 Tools r17 to r20 the Post-Install process for IDB2 encounters the failure: WRNG.LEN.RECORD IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12 When copying the r17 Profile dataset to the new r20 version.
Environment
Release: Component: IDB2
Cause
The r17 REQUESTS PDS library was incorrectly specified as the input file, and it should have been the r17 VSAM PROFILE dataset.
Resolution
Trying to REPRO a PDS to a VSAM file is not supported. The r17 input file for this process must also be a VSAM file.