wasp probe with error Unable to add the resource at ... to the cache for web application

book

Article ID: 131723

calendar_today

Updated On:

Products

DX Infrastructure Management NIMSOFT PROBES

Issue/Introduction



March 02 14:21:34:231 WARN [Catalina-utility-1, org.apache.catalina.webresources.Cache] Unable to add the resource at [/html/themes/_unstyled/images/common/activate.png] to the cache for web application [] because there was insufficient free space available after evicting expired cache entries - consider increasing the maximum size of the cache

Environment

Release:
Component: UIMUMP

Resolution

This can be cleared up by increasing the cacheMaxSize on the UMP server. Update the following:

C:\Program Files (x86)\Nimsoft\probes\service\wasp\conf\context.xml

Increase the size of the cache using the following:

<?xml version='1.0' encoding='utf-8'?>
<Context>
  <Resources cachingAllowed="true" cacheMaxSize="102400" />
  <!-- Disable session persistence across restarts. -->
  <Manager pathname="" />
</Context>


Note: The default without the line added to the file is 10240 (10 meg).