PSA0125 SSA INITIALIZAION FAILED when starting the Xmanager



When I start the Xmanager why do i get this message?

PSA0125 SSA INITIALIZAION FAILED. PSACOEC0 VERIFICATIOV FAILED 

 

 

Environment

z/os

Resolution

This is normally caused trying to load a copy of module PSACOEC0 into storage 

but it cannot because there is already a version there. 

 

Normally this is a copy from a previous release.

Things to Check

1) There is not a copy in the linklist

2) The Apf libraries do not hold a copy of the module

3) Check that the Xmanager job is using the correct and current datasets

4) Verify the datasets in the DSNAMExx member of the CDBAPARM library are correct