[DUAS] Display run shows the default value of variables in uproc and not the value defined during the run
book
Article ID: 131446
calendar_today
Updated On:
Products
CA Automic Dollar Universe
Issue/Introduction
Display run shows the default value of variables in uproc and not the value defined during the run. This issue happens on DUAS version prior to v6.10.01 Steps to reproduce: - Create a Uproc A with a Variable uxSIMULATION=N - Run this uproc with uxSIMULATION=N - Double click on the run -> the Variable field shows uxSIMULATION = N - Update the Uproc -> change the uxSIMULATION=Y - Double click on the previous run again -> the Variable field shows uxSIMULATION=Y
Environment
Release: Component: ADLRUN
Resolution
This issue has been found and fixed on DUAS v6.10.01
Job history is taken into account. Variable value will be updated on Run Show if job history is unchecked. Variable value will keep its previous value if job history is checked.