Upgrade to 9.02 fails: Failed to stop monitors running in the UIM Server
book
Article ID: 131054
calendar_today
Updated On:
Products
DX Infrastructure ManagementNIMSOFT PROBES
Issue/Introduction
Due to an upgrade of UIM 8.5.1 server to UIM v9.0.2, we saw the following errors:
"Failed to stop monitors running in the UIM Server instance."
Cause
- service_host probe was red - upgrade was actually completed
Environment
- UIM 8.51 upgrade to 9.0.2 - hub 7.96 - Database: Oracle 122c - RHEL Linux 6
Resolution
- service_host was red post-install - Deactivated service_host as it is deprecated now in UIM v9.0.2 and replaced by wasp - Rt-click deleted the service_host probe - rm -rf service_host - probeDiscovery queue was not processing - Emptied the queue, added some more memory for the discovery_server and then the queue successfully processed and continued processing. - Checked hub and controller and other probes and everything checked out fine.