UVC Job Runs freezes after changing the Filters
search cancel

UVC Job Runs freezes after changing the Filters

book

Article ID: 131033

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

When displaying the Job Runs and changing the UVC default filter "Start Date" to an older value than the default one, to for instance "-10 Days" or "*", the console becomes not responsive and remains frozen for quite some time.

In univiewer.log the following kind of errors appear:

|DEBUG||LockDetector-0|com.orsyp.util.LockDetector|GUI was frozen for XXX milliseconds.
and:
|ERROR||AWT-EventQueue-0|com.orsyp.kmeleon.document.runlist.model.RunListTableModel|ERROR : getValueAt 3 error size = 0 
...
|ERROR||AWT-EventQueue-0|com.orsyp.kmeleon.document.runlist.view.renderer.RunListTableCellRenderer|Error in table getTableCellRenderer 
|ERROR||AWT-EventQueue-0|com.orsyp.kmeleon.document.runlist.view.renderer.RunListTableCellRenderer|
java.lang.Thread.getStackTrace(Unknown Source) 
...

|WARN ||AWT-EventQueue-0|com.orsyp.kmeleon.document.runlist.model.RunListTableModel|After Error => Sort all

Environment

Univiewer Console 6.8 and higher

Cause

This issue was introduced in Univiewer Console 6.8

Resolution

Update to a fix version listed below or a newer version if available.

Fix version(s): 
Component: Univiewer.Console
Dollar Universe 6.10.01 - Released 29th May 2019