I ran CAIRIM and CAVHCONF to turn on the feature for CA InterTest CICS, CA InterTest Batch, CA SymDump CICS and CA Symdump Batch but result of the CAVHCONF execution shows all products are turn off. How can I correct this problem?
search cancel

I ran CAIRIM and CAVHCONF to turn on the feature for CA InterTest CICS, CA InterTest Batch, CA SymDump CICS and CA Symdump Batch but result of the CAVHCONF execution shows all products are turn off. How can I correct this problem?

book

Article ID: 13085

calendar_today

Updated On:

Products

InterTest - CICS InterTest - Batch InterTest VSE - CICS SymDump for CICS SymDump Batch

Issue/Introduction



When the system IPL, CAIRIM job run with CAVHCONF step and it shows as all products are turn off.

CAVH003I CAVHCONF LOADED
IEF196I CAVH003I CAVHCONF LOADED 

CAVH004I PRODUCT INTENT: DYNAMIC OPTION ON
IEF196I CAVH004I PRODUCT INTENT: DYNAMIC OPTION ON 

CAVH004I PRODUCT INTENT: INTBAT OPTION OFF
IEF196I CAVH004I PRODUCT INTENT: INTBAT OPTION OFF 

CAVH004I PRODUCT INTENT: SYMDUMP OPTION OFF
IEF196I CAVH004I PRODUCT INTENT: SYMDUMP OPTION OFF 

CAVH004I PRODUCT INTENT: SYMCICS OPTION OFF
IEF196I CAVH004I PRODUCT INTENT: SYMCICS OPTION OFF 

CAVH004I PRODUCT INTENT: INTCICS OPTION OFF
IEF196I CAVH004I PRODUCT INTENT: INTCICS OPTION OFF 

CAS9130I - MODULE CAVHINIT COMPLETE, RC=00
IEF196I CAS9130I - MODULE CAVHINIT COMPLETE, RC=00 

After CAIRIM job finished, I rerun CAVHCONF job again then all product feature turn on.

CAVH003I CAVHCONF LOADED
CAVH004I PRODUCT INTENT: DYNAMIC OPTION ON
CAVH004I PRODUCT INTENT: INTBAT OPTION ON
CAVH004I PRODUCT INTENT: SYMDUMP OPTION ON
CAVH004I PRODUCT INTENT: SYMCICS OPTION ON
CAVH004I PRODUCT INTENT: INTCICS OPTION ON 

 

How can I correct the IPL time CAIRIM process so it does not need to run CAVHCONF 2 times?

Environment

Z/OS

Resolution

There are 5 intent switches in CAVHCONF:

1)  DYNAMIC
2) INTBAT (InterTest Batch)
3)  SYMDUMP (SymDump Batch)
4)  SYMCICS (SumDump CICS)
5)   INTCICS (InterTest CICS)

 

If DYNAMIC is on calls are placed to get the LMP status for the presence of a license key for products numbered 2 through 5. For each of the 4 products, if the LMP key is found for the product the intent switch is turned on, else it is turned off.

 

If the CAIRIM process is not finish for LMP keys and CAVHCONF job run first then CAVHCONF could not find the LMP keys for the products and features were turn off. 

 

Make sure CAIRIM's LMP process done first and then run CAVHCONF.

Additional Information

CA InterTest and SymDump Configuration guide