UIM - SNMPcollector issue with device discovery
book
Article ID: 130812
calendar_today
Updated On:
Products
DX Unified Infrastructure Management (Nimsoft / UIM)
CA Unified Infrastructure Management On-Premise (Nimsoft / UIM)
CA Unified Infrastructure Management SaaS (Nimsoft / UIM)
Show More
Show Less
Issue/Introduction
snmpcollector device discovery is not working.
Error: Could not find discovery_server probe at /Domain_hub/Hub_name/h ubrobot/discovery_server Ensure the address is correct, and that the discovery_server probe is running.
Environment
UIM v9.0.2 or higher
snmpcollector v3.44 or higher
Cause
Difference between the discovery_server probe NimBUS address and the NimBUS address specified in the snmpcollector.
Resolution
One character in the address was a different case. /Domain_hub/Hub_name/Hubrobot/discovery_server /Domain_hub/Hub_name/h ubrobot/discovery_server Corrected the discovery _server path via the Admin Console -> SNMP configuration to point to the correct discovery_server address which is on the Primary hub.