IDMS PMIM delay in function after startup
search cancel

IDMS PMIM delay in function after startup

book

Article ID: 130543

calendar_today

Updated On:

Products

IDMS IDMS - Database IDMS - ADS

Issue/Introduction



It appears that for some time after startup the PMIM facility does not function.

At the bottom of the main menu screen it shows 

"No Intervals Have Been Collected Yet "

None of the menu functions do anything.

At some point later the main menu shows

"Interval Monitor is Online and Collecting Data "

and all functions work as expected

What causes this delay?

  

Environment

Release: IDADSO00100-18.5-ADS-for CA-IDMS
Component:

Resolution

Until the first Interval has been collected, PMIM has nothing to report on.

Example:
  #PMOPT specifies  INTVSIZ=10 

  Interval is 10 minutes.

  The interval is based on 10 minute increments of the Time of Day.
  It is not based on the time the CV was started.

  So if CV comes up at 08:11:36,  PMIM will show that  "No Intervals Have Been Collected Yet "  until 08:20:00.
   At 08:20:00 PMIM will show   "Interval Monitor is Online and Collecting Data "  and you will have the first interval's stats.

   If CV had started at 08:18:12  the delay would be less.  The first interval will also be available at 08:20:00.