Auditor option 2.1.2 gets error message IEC141I 013-18
search cancel

Auditor option 2.1.2 gets error message IEC141I 013-18

book

Article ID: 129851

calendar_today

Updated On:

Products

Auditor for z/OS

Issue/Introduction



Running Auditor option 2.1.2 that checks Parmlib Member Status gets error

IEC141I 013-18,IGG0191B,$SCSGRRX,STEP2,SYS00009,123C,MVSRES,
SYS1.PARMLIB(COMMND00) 
 
What is causing this?

Environment

Release:
Component: EXAMIN

Resolution

Option 2.1.2 reads the IEASYSxx members in the parmlib. Auditor then tries to open the associated members. For example:

CLOCK=00,
CMD=(00,V0),

Auditor would then try and open CLOCK00, COMMND00, and COMMNDV0.  If those members do not exist, you will get that error message.  Check your IEASYSxx members, remove items that point to non-existent members.  If the complete IEASYSxx member points to non-existent members, then delete that IEASYSxx member from parmlib.
 
If you are getting something different, open a support case.