What to validate when message LAE0005E Unable to open LADXTRCT, LADXCNTL or LADREPT DCB occurs
when running Log Analyzer Quiet Point Analysis Report?
Validate the SDSF output if the allocation for the report was generated:
.ALLOC FI(LADREPT) +
BLKSIZE(7448) LRECL(137) RECFM(VB) +
SYSOUT(*)
RETCODE = 0
If the allocation for the report is not generated go to the Report File Specification and set the Allocation Parameters.
Therefore please check if New Allocation ==> Y is set at panel LAOS4 Process Log - Output Specifications:
REPORT FILE SPECIFICATIONS
Destination ==> S ( D - Dataset, S - Sysout, T - Terminal
Dataset Name ==>
Disposition ==> NEW ( SHR , OLD , NEW , RPL )
New Allocation ==> y ( Y - Specify allocation info, N - Use
Followed at panel LAALLOC Allocate File checking the ALLOCATION PARAMETERS
Volume Serial ==> ( Blank for authorized default )
Space Units ==> CYLINDER ( BLKS, TRKS or CYLS )
Primary Quantity ==> 20 ( In above units )
Secondary Quantity ==> 10 ( In above units )
Record Format ==> VBA
Record Length ==> 137
Block Size ==> 7448
Generic Unit ==> SYSDA ( Unit name for NON-SMS dataset)
Model DSCB (GDG) ==>