Issue/Introduction

Performed maintenance on Disk 12.5. Any job that uses BACKUPCC now gives message ADR411W 4256 for any dataset in use. The job now fails with a RC=04. 

Environment

Release: Disk-Backup and Restore 12.5

Resolution

PTF RO98860 and its PRP SO00305 changed the return code processing when we use DSS either via USEDSSIO or BACKUPCC. ADR messages with an E (like ADR960E) will cause an RC of 8 since DDS had an error.

PTF SO00305 corrects the improper return code processing.