Opening saved report in UMP gives the Error " Unable to locate new series". While generating manually the report is generating fine.
I am getting an Error " Unable to locate new series" while opening saved report in UMP. While generating manually, the report is generating fine.
Environment
CA UIM 8.5 UMP 8.5 probe interface_traffic 5.45
Resolution
Error " Unable to locate new series" while opening saved report in ump is usually caused by trailing space in the source name. This should be able to be fixed by going into the interface_traffic probe GUI, right-clicking on the relevant device/switch in the left sidebar, and selecting rename to remove the trailing space in the device name. Check and remove the space in the hostname to resolve the issue.
Additional Information
Interface_traffic - This probe is no longer supported as of October 1, 2017. This probe is replaced by the snmpcollector probe.