CTS Abend S806 for PGM=EARL
search cancel

CTS Abend S806 for PGM=EARL

book

Article ID: 129670

calendar_today

Updated On:

Products

CA 1 Flexible Storage CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options

Issue/Introduction

After upgrade to CA 1 Release 14.0 CTS abended with: 

CSV003I REQUESTED MODULE EARL NOT FOUND 
CSV028I ABEND806-04 JOBNAME=CTS STEPNAME=CTS 
IEA995I SYMPTOM DUMP OUTPUT 
SYSTEM COMPLETION CODE=806 REASON CODE=00000004 
TIME=00.44.59 SEQ=01877 CPU=0000 ASID=0092 
PSW AT TIME OF ERROR 070C1000 813BF642 ILC 2 INTC 0D 
NO ACTIVE MODULE FOUND 
NAME=UNKNOWN 
DATA AT PSW 013BF63C - 8400181E 0A0D18FB 180C181D 
GR 0: 00001F00 1: 84806000 
2: 00000000 3: 00000000 
4: 00000000 5: 009FF7F8 
6: 000000FF 7: 00000000 
8: 7F5E9168 9: 013BFB68 
A: 00000000 B: 00000000 
C: 00000000 D: 7F5E9168 
E: 84806000 F: 00000004 


There was no problem with CA 1 Release 12.6.

Environment

Release:
Component: 1

Cause

The EARL program is used by the optional LAB subtask of CTS for external label printing. 
Obviously after the CA 1 upgrade to Release 14.0 the EARL program is no longer in the linklist concatenation causing the abend.
 

Resolution

EARL is part of CA Common Services and is installed into the CCCSLOAD library.
Be sure the CCCSLOAD library is in the linklist concatenation or defined as STEPLIB in the CTS procedure
or remove START LAB from the CTSSTART member, if the optional LAB subtask is no longer used.