CA Datacom 15.0 PTF RO91112 SMP/E ACCEPT RC 04 GIM24701W warnings
search cancel

CA Datacom 15.0 PTF RO91112 SMP/E ACCEPT RC 04 GIM24701W warnings

book

Article ID: 12888

calendar_today

Updated On:

Products

Datacom Datacom/AD CHORUS SOFTWARE MANAGER

Issue/Introduction



CA Datacom version 15.0 PTF RO91112 and 15.1 PTF RO91115 SMP/E ACCEPT receives RC 04 and several warnings:

 

GIM24701W SMP/E COULD NOT OBTAIN LINK-EDIT PARAMETERS FOR LOAD MODULE mmmmmm FOR SYSMOD RO91112. DEFAULTS WERE USED. 


Is this acceptable? 

 

Environment

z/OS

Resolution

The GIM24701W warnings are acceptable and as expected.

GIM24701W is normal when SMP/E accepts elements into the distribution libraries (DLIB) for the first time.    

PTF RO91112 delivers those SQI Interface modules the first time to CA Datacom 15.0.                          

Additional Information

The full set of SMP/E ACCEPT messages are as follows:




SMPOUT.PNG