Receiving CAUAJM_W_10047 Config file contains invalid input: EventServer from client utilities

book

Article ID: 128436

calendar_today

Updated On:

Products

CA Workload Automation AE - Business Agents (AutoSys) CA Workload Automation AE - Scheduler (AutoSys) CA Workload Automation Agent

Issue/Introduction

When running a client utility such as jil or autorep, the command works fine. However, a warning message is printed prior to the output...

CAUAJM_W_10047 Config file contains invalid input: EventServer

What causes this warning and how can it be corrected?

Cause

The warning occurs when the config.$AUTOSERV file contains a parameter that is not recognized by the client utility. For this particular message, it is complaining about the EventServer parameter. This happens when usingĀ a client utility that is version 11.3.5 or higher with a config.$AUTOSERV file that is from version 11.3. As of WAAE 11.3.5, the EventServer config parameter was changed to EventServer_1. Without the _1 at the end of the parameter name, 11.3.5+ client versions do not recognize the older EventServer parameter and print the warning. It does not cause the command to fail, but it will continue to print the warning every time it is run.

Environment

WAAE 11.3.5 or higher
Database: Any
O/S: Any

Resolution

To stop this warning from occurring, modify the config.$AUTOSERV file and change the EventServer parameter name to EventServer_1.