Cust reported that the ReportCenter component was not working after
the upgrade of NetMaster from 12.1 to 12.2.
REPTEST command returned these messages:
WRST0000 ReportCenter Function Test on NMYYYYY (Dormant
Control Region)
WRST0003 No action taken -- NMYYYYY ReportCenter control
region functions
WRST0003 are not yet fully implemented.
WRST0098 ReportCenter Function Test completed with no
errors or warnings.
Note: NMYYYYY comes from the real region name.
Cust managed to fix this problem by adding:
WRHFS1=(path of library that ReportCenter runs from)
to member IIAPARMS for future rollouts.
-
The immediate fix was to create INI member in RUNSYSIN and set
$WR$HFS1 = &STR (path of library that ReportCenter runs
from) followed by a NetMaster region startup.
This knowledge document that this author published in Jan 2019
was helpful:
https://comm.support.ca.com/kb/wrinwi18-trying-to-generate-java-task-jcl/kb000124110
Please review these NetMaster documentation pages for additional
WRHFS1 information: