Running CADB2C11 to rebind/link fails with a -0805 after upgrading to DB2 v11.
Running CADB2C11 to rebind/link fails with a -0805 after upgrading to DB2 v11.
To bind and run the conversion utility you need at least the following list of maintenance:
ENF/DB2:
RO57094
++MOD(CASRDB2V) DISTLIB(AAW5MOD ) .
++MOD(CASR230 ) DISTLIB(AAW5MOD ) .
++MOD(CASR230G) DISTLIB(AAW5MOD ) .
++MOD(CASR230I) DISTLIB(AAW5MOD ) .
++MOD(CASR230J) DISTLIB(AAW5MOD ) .
++MOD(CASR230K) DISTLIB(AAW5MOD ) .
++MOD(CASR230Z) DISTLIB(AAW5MOD ) .
TSS/DB2:
RO54332
++MOD(CADB2C11) DISTLIB(AADBMOD0) .
++MOD(CADB2TCN) DISTLIB(AADBMOD0) .
CM-BAV (CA DB2 Common Code):
RO55816
++MOD(CADB2SEC) DISTLIB(ABAVMOD0) .
++MOD(CADB2XAC) DISTLIB(ABAVMOD0) .
RO65361
++MOD(CADB2C11) DISTLIB(ABAVMOD0) .
Please check you SMP/E zones for each product. TSS/DB2 and CM-BAV should both be in the same SMP/E environment. ENF/DB2 may be in a different set of zones depending on how your site does maintenance for CA products. I supplied the ++MOD entries from each PTF to show what MOD entries are replaced and what DLIB they should be part of. If the PTFs are not ACCEPTed you shoul dbe able to list the ++MOD entries in SMP/E to see what LMOD each should be part of.