Issue/Introduction

When I deploy the ADE probe to a secondary hub I get an error message about the prob_discovery queue.

How do I resolve this?



Environment

UIM 9.X and earlier
ADE 9.X and earlier

Resolution

When deploying ADE for bulk deployment to a secondary hub there are some setup things that need to be done as well.

1) the discovery_agent needs to be deployed to the hub

2) a message type of probe_discovery. This is usually just added to the queue that is handling the QOS messages.

https://docops.ca.com/ca-unified-infrastructure-management/9-0-2/en/installing/discover-systems-to-monitor/configuring-discovery/configure-discovery-queues



Once the above two steps are done you should no longer get the error message you have provided.