HSM tape protected by RACF
search cancel

HSM tape protected by RACF

book

Article ID: 125719

calendar_today

Updated On:

Products

CA 1 Flexible Storage CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options

Issue/Introduction

There was a tape XXXXXX used by HSM on 1/17 and released on 1/18 and the tape was scratched by TMSCLEAN on 1/18 at 18:00.

It was immediately used for a scratch request by job XXXXXX and was rejected.

IEC089I 03 RACF VOL SET CONFLICT XXXX,XXXXXX,XXX XXXX,DUMP
IEC518I SOFTWARE ERRSTAT: RACFPROT F4FF,XXXXXX,SL,XXXXXXXX,DUMP
IEC502E R F4FF,XXXXXX,SL,XXXXXXXX,DUMP

Is a protected volume released by RACF immediately when it is scratched by TMSCLEAN?

Environment

Release:
Component: 1

Resolution

CA 1 is not going to update a RACF profile to remove these volumes from the list. That will have to be done manually or via something in HSM to tell RACF to remove the volume. Please contact IBM HSM and/or RACF support about this. CA 1 does not update the TAPVOL information in RACF. We will update the TMC and notify the ATL/VTS that we scratched the tape.

Here is the link to the IBM documentation:

https://www.ibm.com/support/knowledgecenter/en/SSLTBW_2.3.0/com.ibm.zos.v2r3.arcf000/tapes.htm