DatacomDATACOM - ADCISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertware
Issue/Introduction
Datacom Version 15.1 PTF SO06314 only affects module DBACUPR. It is not an active module and cannot be NEWCOPYed. Can module DBACUPR be deployed by copying it to the active Datacom load library replacing the prior version the module? And, does the Datacom Multi-User (MUF) have to be cycled after it is copied?
Environment
z/OS
Resolution
DBACUPR is only used in the DBUTLTY address space during an ACCT EDIT or CATALOG. Hence NEWCOPY is not needed for DBACUPR in the MUF address space. Module DBACUPR module can be deployed without cycling the MUF.
Additional Information
For information on load modules eligible for NEWCOPY, refer to CA Datacom Core - 15.1 section "NEWCOPY" https://docops.ca.com/ca-datacom/15-1/en/administrating/ca-datacom-db-database-and-system-administration/using-the-multi-user-facility/modifying-muf-startup-options/newcopy