TMSUPDTE can be used to fix ERR10's, ERR11's, and ERR39's.
ERR 10 and ERR11 control statement examples:
VOL XXXXXX,NODSN,NOCHAIN
REP VOLSEQ=0001
REP NEXTVOL=HEXZEROS
OR
If what is above does not work use:
VOL XXXXXX,NODSN,NOCHAIN
REP 1STVOL=HEXZEROS,NEXTVOL=HEXZEROS,PREVOL=HEXZEROS
For ERR39's, use what is below:
VOL XXXXXX,NODSN,NOCHAIN
REP EXPDT=2019/003
REP VOLSEQ=1
Please send in a new TMSPTRs output after running the job.