When I ran the CA Endevor install job SCM9ACCP, it gets a RC=04. Is that acceptable?
search cancel

When I ran the CA Endevor install job SCM9ACCP, it gets a RC=04. Is that acceptable?

book

Article ID: 12406

calendar_today

Updated On:

Products

Endevor Endevor Natural Integration Endevor - ECLIPSE Plugin Endevor - Enterprise Workbench

Issue/Introduction



When I ran the CA Endevor install job SCM9ACCP, it gets a RC=04.

Is that acceptable?

Environment

Release:
Component: ENDBAS

Resolution

The reason for the RC 4 must be checked.

Warnings in LINK-EDIT processing are normally acceptable. However, review the cause of the RC 4 to verify they are acceptable. 

 

GIM23913W    LINK-EDIT PROCESSING FOR SYSMOD RO81348 WAS SUCCESSFUL FOR MODULE 

             LIBRARY. THE RETURN CODE WAS 04. DATE 16.354 - TIME 13:52:55 - SEQ

             SMP00002.                                                         

 IEW2278I B352 INVOCATION PARAMETERS - LET,LIST,SIZE=((2000K,12K),NCAL,RENT,REUS,REFR,AC=1,AMODE=31,RMODE=ANY,NCAL 

 IEW2322I 1220  1    INCLUDE SMPWRK3(BC1PAPI)               RO81348       SEQ # 000011 

 IEW2322I 1220  2     IDENTIFY BC1PAPI('RO81348')                               

 IEW2322I 1220  3     SETSSI 00016046                                           

 IEW2322I 1220  4    NAME BC1PAPI(R)                        MAX ACCEPTABLE RC=04

 IEW2454W 9203 SYMBOL BNVPEINT UNRESOLVED.  NO AUTOCALL (NCAL) SPECIFIED.       

 IEW2646W 4B07 ESD RMODE(24) CONFLICTS WITH USER-SPECIFIED RMODE(ANY) FOR SECTION WC1PAPI.

 IEW2650I 5102 MODULE ENTRY NOT PROVIDED.  ENTRY DEFAULTS TO SECTION BC1PAPI.