DCI Controller region getting a S0C4 in UNKNOWN module at startup
search cancel

DCI Controller region getting a S0C4 in UNKNOWN module at startup

book

Article ID: 123183

calendar_today

Updated On: 10-03-2024

Products

Dynamic Capacity Intelligence

Issue/Introduction

Just installed Dynamic Capacity Intelligence (DCI) 1.5 0300 on an LPAR where no other Mainframe solutions are running. Common Services has been installed and CAIRIM started at IPL.
 
When the DCI Controller region is started, a S0C4 in UNKNOWN module is returned. The Controller region doesn't work and it must be cancelled. 

Environment

Dynamic Capacity Intelligence (DCI) 1.5 0300 on z/OS

Cause

ZDCLOGR contains the following error messages:
IRX0253E Abend in external function ZDCC0011.                                  
  2360 +++         x=zdcc0011(check_lmpkey,g.config.key)                       
  3543 +++      call check_key                                   /*V143*/      
    80 +++   call req_init                                                     
IRX0040I Error running ?, line 2360: Incorrect call to routine                 
     1 +++ CALL ZDCC0010                                                       
IRX0040I Error running ZDCC0001, line 1: Incorrect call to routine      


Verified that CAIRIM is running with a very old maintenance level.
      

Resolution

Applied all the available maintenance for CAIRIM and the other Common Services functions that are applied. IPLed the LPAR, restarted DCI and the S0C4 abend no longer occurred.