We started getting the GSVX077E message after an IPL. I read the description of the message, saying that its swapped and mvs can't or wont swap it in. Can we safely ignore this message, or is there something that needs to be done? GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BA GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00C2 GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00C2 GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00C2 GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BA GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00C2 GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BA GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BA GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BD GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BD GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BA GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BD
Environment
Release: Component: SYSVW
Resolution
The error messages that you have asked about: GSVX077E (JVMDATA) NSS-PC failed, timeout in ASID 00BA can be ignored. They cause no problem and are fixed in PTF10 due to come out this month 12/2018