Compliance Event Manager Sysplex implemntation with multuple lpars. When the CEVM CEMWHSE, CEMMON and CEMALERT component tasks are started the task abend with CCSR010E ECALCMGR S0C4 at 1904A52E LMOD ECALCMAP CSECT ECALCMAP +0364AE . What causes these abends?
IEF403I CEMWHSE - STARTED - TIME=13.45.02 CEM0201I CEM Listener Activation CEM0206I CEM Listener Options Processing CEM0207I CEM Listener Options Processing Success CEM0404I CEM Listener Processing Data Warehouse Options CEM0419I CEM Data Warehouse Option DBTYPE= DATACOM CEM0419I CEM Data Warehouse Option DCOMMUF= CEMEMUF CEM0956I CEM listener using set PNCPOC CEM0957I Configuring alert settings for PLEX=TECPLEX, LPAR=E09X, STC=CEMWHSE CEM0960I email type=CS SMTP, domain=, writer name=, job class= CEM0961I WTO descriptor code=, route code= CCSR010E ECALCMGR S0C4 at 1904A52E LMOD ECALCMAP CSECT ECALCMAP +0364AE CEMWHS CCSR021I OWNER = CA CEM R6.0 CCSR022I MODULE = ECALCMAP FMID = CCEM600 RMID = ST04968 CCSR060I BREAKING EVENT ADDRESS: 00000000 08B5E7C8 CCSR061I PSW: 47851400 80000000 00000000 1904A52E CCSR062I ILC: 04 INTERRUPT CODE: 11 CCSR067I COMPLETION CODE S0C4 REASON CODE 00000011
Environment
Release: Component: CEVM
Resolution
If the secondary lpars share the same repository and do not run the CEMELDAP task for CA LDAP Server or the CEMETOM for the TOMCAT server only the primary lpar needs a MAPDB file and that MAPDB file can be shared by the other lpars. If an empty MAPDB file is pointed to by the secondary CEVM component tasks such as CEMWHSE, CEMMON and CEMALERT the tasks may abend due to an invalid MAPDB file.