The message DC329019 V10 T22 Resynchronization completed successfully was not written to the log at startup. Why would this message be missing at startup?
Release: All supported releases
Component: IDMS/DB
The DC329019 message can be received when there is a DDS connection between two CVs and those CVs have communicated successfully with each other at some point.
If not using DDS distributed transactions the DC329019 message can also be received when NODE statements have been defined in the SYSGEN for UCF connections between IDMS/DC systems.
Enter into 19.0 CV and enter command:
DCMT D DIST RM
The command DCMT D DIST RM shows this on the CV:
RM Name Status Startup time (UTC) PndResync
TECHDC50::DSI_CLI Open 2016-11-30-18.46.06.107469 0
TECHDC50::DSI_SRV Open 2016-11-30-18.46.06.107469 0
RM Name Status Startup time (UTC) PndResync
<your-idms-cv-name>::DSI_CLI Open 2016-11-30-18.46.12.855827 0
<your-idms-cv-name>::DSI_SRV Open 2016-11-30-18.46.12.855827 0
DCMT V DIST RM '<your-idms-cv-name>::DSI_CLI '
and
DCMT V DIST RM '<your-idms-cv-name>::DSI_SRV'
Shutdown and restart the CV, then no DC329019 messages appear until a request from one CV to the other CV thru DDS. Then DCMT D DIST RM will show the SRV or CLI entries again.