With CA SYSVIEW for DB2, will Forbidden, Expensive, Restricted IFCIDS cause problems when used?
search cancel

With CA SYSVIEW for DB2, will Forbidden, Expensive, Restricted IFCIDS cause problems when used?

book

Article ID: 122446

calendar_today

Updated On:

Products

Bind Analyzer for DB2 for z/OS SQL-Ease for DB2 for z/OS SYSVIEW Performance Management Option for DB2 for z/OS Plan Analyzer for DB2 for z/OS Subsystem Analyzer for DB2 for z/OS

Issue/Introduction

The following alert  was displayed in the exception:
Message: * High Severity Exception * DBGHC025E CA SYSVIEW for DB2 data collector BWZXDSN contains expensive IFCID(s) in online statistics history file: 0055, 0144, 0350 Explanation: The data collector SYSPARM option HIST-STATS-RECS contains one or more expensive IFCIDs as identified in the message text. These IFCIDs will not be used by CA SYSVIEW for DB2, can cause high DB2 overhead, and will potentially flood the CA SYSVIEW for DB2 online history file causing meaningful history data to be unavailable. But they are used for Auditing purpose (55 - SET CURRENT SQLID and 144 - READS towards DB2 AUDITED Table). Will this configuration cause problem?
 

Environment

Release:
Component: CIDB

Resolution

Yes, you could experience the potential problems caused by the expensive IFCIDs. It's up to you to evaluate and decide what best serve the interest of your shop. Use of the expensive IFCIDs for audit or the risks listed.