It may happen that you suffer this Abend when shutting down Netmaster:
 N01101 NetMaster ABEND N-1U2-01 ID=H245NM JN=SOLVY DT=2018324 TM=0455333 2
 IST663I IPS SRQ REQUEST FROM ISTAPNCP FAILED, SENSE=08570003 655
 IST664I REAL OLU=IIGNETQA.H246NM REAL DLU=IIGNETQA.H245NM
 IST889I SID = CE7F4EEACE7E67CB IST1138I REQUIRED RESOURCE IIGNETQA.H245NM NOT ACTIVE IST314I END
*N01102 SRC=AB PRD=NetMaster INTLVL=080100 SP=0003 ABC=N-1U2-01
*N01103 ALM=NM076 ALO=00002062 ACS=NM0001U2 ACO=00000E22

...

Environment

Release: SLOPFC00200-12.2-NetMaster-File Transfer Management
Component:

Resolution

A timing problem with task shutting down and causing this Abend is resolved by applying PTF SO06416.