Date Simulator

Issue/Introduction

The client has just installed CA Date Simulator into a new LPAR and is getting the following messages when running WARPMAIN:

WARP100I: INITIALIZATION IN PROGRESS                                            
WARP086I: DATE SIMULATOR NOT STARTED. PC# INCORRECT. CHECK FOR CONFLICTING PRODUCT

WARP100I: INITIALIZATION IN PROGRESS
WARP086I: DATE SIMULATOR NOT STARTED. PC# INCORRECT. CHECK FOR CONFLICTING PRODUCT
SLM001 RDR-OFF Q-WAIT ENQ-WAIT
SLM002 11:12:46 00:00:00 00:00:00
SLM003 JOBNAME STEP STEPNAME PROCSTEP PGM= EST-COST CCODE
SLM004 DATESIM 1 DATESIM STARTING WARPMAIN $N R0004 ********* IEF404I DATESIM - ENDED - TIME=11.12.46
SLM005 TOTL-COST $ ADJ-COST $
SLM006 STEPS: TOTAL RUN FLUSHED U-ABEND S-ABEND

Environment

Release:
Component: TWARP

Resolution

Message WARP086I means that the system PC (program call) TIME Service routine number is not X’00000321’ as expected, therefore Date Simulator thinks there is another product that is using the Time Service routine running on the system and will not initialize. 

To determine the value in the system function table that normally represents the Time service routine, I will need an SVC dump, however, even with this information, I may not know what replaced it but I can give it a try. Please do the following to get an SVC dump: 

Enter command: DUMP TITLE=‘DUMP MASTER’ 

The system will display the following message: 

IEE094D SPECIFY OPERAND(S) FOR DUMP COMMAND 

Respond with the following: 

SDATA=(PSA,CSA,LPA,LSQA,ALLNUC,SQA,SWA,TRT),END 

Please send the SVC dump.