Issue/Introduction

I have created new SECFILE and VSAMFILE with AES256 Since, the backup of VSAMFILE fails :
01.02.05 STC17073 ---- TUESDAY, 20 NOV 2018 ----
01.02.05 STC17073 TSS9096I SECURITY FILE BACKUP COMMENCING
01.02.12 STC17073 TSS9145I VSAMFILE FILE BACKUP COMMENCING
01.02.12 STC17073 IEC161I 084(048,054,IGG0CLFQ)-003,TSS15,TSS STEP00,VSAMBK 373 IEC161I T8SXU.CAI.TSS.VSAMBKUP,,CATLG.TET8.UCATMVS
01.02.12 STC17073 *TSS9147E VSAMFILE FILE BACKUP FAILED
01.02.12 STC17073 TSS9094I SECURITY FILE BACKUP COMPLETE 010212 TSS9145I VSAMFILE FILE BACKUP COMMENCING 010212IDCAMS SYSTEM SERVICES TIME:
01 010212 010212 REPRO INFILE(VSAMFILE) OUTFILE(VSAMBKUP) REUSE 010212IDC3300I ERROR OPENING T8SXU.CAI.TSS.VSAMBKUP 010212IDC3351I ** VSAM OPEN RETURN CODE IS 232 010212IDC0005I NUMBER OF RECORDS PROCESSED WAS 0 010212IDC3003I FUNCTION TERMINATED. CONDITION CODE IS 12 010212 010212IDC0002I IDCAMS PROCESSING COMPLETE. MAXIMUM CONDITION CODE WAS 12 010212 TSS9147E VSAMFILE FILE BACKUP FAILED

Environment

z/os

Cause

REUSE not specified

Resolution

Create VSAM Backup file with theĀ  REUSE option