Why if one of the XITn is coded in the TMOOPTnn and the module doesn't exist, or is not loaded, TMSINIT get a U0006 abend on TMSINIT USER COMPLETION CODE=0006 TIME=12.04.17 SEQ=00017 CPU=0000 ASID=0099 PSW AT TIME OF ERROR 078D1000 00008F10 ILC 2 INTC 0D ACTIVE MODULE ADDRESS=00000000_00007F68 OFFSET=00000FA8 NAME=TMSINIT DATA AT PSW 00008F0A - 00181610 0A0D4110 000B4100 GR 0: 80000000 1: 80000006 2: 0000A428 3: 000097B8 4: 00009808 5: 00000000 6: 00008834 7: 00F85580 8: 00AFC7E0 9: 00007F68 A: 00008F68 B: 00009F68 C: 151EF5E8 D: 00007FEC E: 000086EE F: 00000000 END OF SYMPTOM DUMP
Environment
Release: Component: 1
Resolution
This behavior of CA1 has been changed with RO96979 -
If a resident exit (TMOOPTxx options starting with XITx) cannot be loaded, TMSINIT will now abend with a U0006 abend just as if the parameter had been in error.
SYMPTOMS: If a resident exit cannot be loaded, processing may not work as expected.
IMPACT: A desired exit is not loaded.
CIRCUMVENTION: Review the output from TMSINIT in detail to see that resident exits are being loaded.