IDMS 19 abended S483 many times in PROD
search cancel

IDMS 19 abended S483 many times in PROD

book

Article ID: 120620

calendar_today

Updated On:

Products

IDMS IDMS - Database IDMS - ADS

Issue/Introduction

IDMS 19 abended S483 many times in PROD
Description

10.46.08 STC22018 *ICH409I 483-050 ABEND DURING RACINIT PROCESSING 
10.46.08 STC22018 +CCSR010E RHDCOS00 S483 at 0000C77A LMOD IDMSDC CSECT RHDCOESA +004FE2 STIDPN4 N/A STIDPN4 
10.46.08 STC22018 +CCSR021I OWNER = CA IDMS R19.0 
10.46.08 STC22018 +CCSR022I MODULE = RHDCOESA FMID = CAGJJ00 RMID = RO95151 
10.46.08 STC22018 +CCSR061I PSW: 07041000 80000000 00000000 04A2AA0C 
10.46.08 STC22018 +CCSR062I ILC: 02 INTERRUPT CODE: 0D 
10.46.08 STC22018 +CCSR067I COMPLETION CODE S483 REASON CODE 00000050 
10.46.08 STC22018 +CCSR064I DATA AT PSW 04A2AA06 : 58F0C30D 0A0D910A C2A5A774 
10.46.08 STC22018 +CCSR065I HOME = 011C PRIMARY = 011C SECONDARY = 011C


The error: 
-------------------------------------------------------------------- 
*ICH409I 483-050 ABEND DURING RACINIT PROCESSING 
----------------------------------------------------------------------- 
The error message is saying: 
" While RACF® was processing a RACINIT request, the RACF manager returned an incorrect return code. " 

In other words, RACF is returning a return code to IDMS that IDMS does not recognize and cannot handle it. 

 

Environment

Release:
Component: IDMS

Cause

The reason for the abends in IDMS is that the RACF dataset is available in read-only mode when it should be shared;
The MVS team found that the problem on the SYSPLEX: MEMBER was because it had SYSPLEX COMMUNICATIONS ENABLED & IN READ-ONLY MODE. 

 

Resolution

To solve that the customer IPL'd and after that they the SYSPLEX member was set to SYSPLEX COMMUNICATIONS ENABLED & IN DATA SHARING MODE. 
 

Additional Information

https://docops.ca.com/ca-idms/19/en/administrating/administrating-ca-idms-system-operations/ca-idms-in-a-sysplex-environment