Does CA Optimizer and CA Optimizer/II refer to the PSASTAK feild ?
search cancel

Does CA Optimizer and CA Optimizer/II refer to the PSASTAK feild ?

book

Article ID: 120597

calendar_today

Updated On:

Products

Optimizer/II

Issue/Introduction

IBM APAR OA55240;
This APAR introduces the OSPROTECT system parameter which specifies the operating system protection mode for unauthorized programs and users.

Software must no longer reference the IHAPSA field PSASTAK. With this PTF, PSASTAK is no longer the beginning of the normal FRR stack. PSACSTK is an existing pointer to the beginning of the normal FRR stack. Software that references PSASTAK must be converted to use PSACSTK as the pointer to the normal FRR stack.The PSASTAK is related to recovery management and the apar itself changes the  definition of the PSASTAK field in module IHAPSA  to PSACSTK and software continuing to reference PSASTAK can receive a S0C4.


  Does CA Optimizer and CA Optimizer/II refer to the PSASTAK feild ?

Environment

z/OS

Resolution

CA Optimizer and CA Optimizer/II does not refer to the PSASTAK feild.