Issue/Introduction

How to correct the following Detector for Db2 for z/OS (PDT) related message:

DT570E: Detector control file allocate failed S99RSC=035C0002

Resolution

1) Entering DTCF on the option line of the Detector main menu.

2) The Detector Create Control File Display should appear.  Enter the name of the new Control File for the Dataset Name prompt and press Enter to create the file.

3) Recycle the Xmanager task to implement the modification.