ECLI Logon failure: the user has not been granted the requested logon type at this computer
book
Article ID: 117338
calendar_today
Updated On:
Products
CA Workload Automation AE - Business Agents (AutoSys)CA Workload Automation AE - Scheduler (AutoSys)Workload Automation Agent
Issue/Introduction
When attempting to run a command through the ECLI to a Windows-based AE instance, the command submission fails and the error returned says... "Logon failure: the user has not been granted the requested logon type at this computer"
Environment
WCC 11.3.6/11.4/12.0 Service Pack: Any AE Environment: 11.3.x/12.0 Windows
Resolution
The user sent to the AE server as part of the ECLI command submission must have interactive logon permission on the AE Windows server. The user sent with the command will be either WCC user or a credential user for the AE server if one has been specified in the "Credentials" tab.
Additional Information
Navigate to Windows Settings\Security Settings\Local Policies\User Rights Assignments