Maximum length for each value in nas probe Auto-Operator
search cancel

Maximum length for each value in nas probe Auto-Operator

book

Article ID: 117265

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction



What is maximum length for each value in nas probe Auto-Operator ?

Resolution

2048 bytes is maximum length for a line in every probe cfg file in robot 7.93.

In robot 9.40 this has been tested as 10000 bytes.

NOTE - The length is total byte count in a line.  This includes any indentations at the beginning of the line. 

In order to account for indentations and key names, we would recommend that the length of any value in a given AO config field should be kept limited to 9900 bytes.

Additional Information

robot 7.93 will crash when line exceeds 2048 bytes.
https://comm.support.ca.com/kb/unable-to-save-very-lengthy-input-to-nas-probe-gui/kb000100761

Attachments

1558694800159000117265_sktwi1f5rjvs16hup.png get_app