ntevl profiles missing from Monitoring tab of UIM 9.01
search cancel

ntevl profiles missing from Monitoring tab of UIM 9.01

book

Article ID: 115932

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

After installing UIM 9.01, there are no ntevl probe monitoring profiles available from the Monitoring tab in the UMP USM portlet.

Environment

UIM 9.01 EA
mon_config_service:  9.00

Cause

By default the ntevl_mcs_templates package is not deployed after installing UIM 9.01.

Resolution

First confirm/configure the mon_config_service probe to automatically migrate new templates:

1. Open the Raw Config GUI for the mon_config_service probe on the primary hub.
2. Select the migration folder from the left-hand pane.
3. Modify the enable_auto_migration key in the right-hand pane and change it to true if it is currently set to false.
4. Apply the change and restart the probe.

Once the mon_config_service probe is configured to automatically migrate new templates, deploy the ntevl_mcs_templates package to the primary hub.

Additional Information

https://docops.ca.com/ca-unified-infrastructure-management-probes/ga/en/alphabetical-probe-articles/mon_config_service-monitoring-configuration-service/mon_config_service-monitoring-configuration-service-release-notes#mon_config_service(MonitoringConfigurationService)ReleaseNotes-(CAUIM9.0.1)UpdateTemplates