After an upgrade to z/OS 2.3 when I try and run CAS9 with a REINIT of CA-1, it fails the load of all the new modules.
book
Article ID: 115406
calendar_today
Updated On:
Products
CISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesDatacom/ADCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertwareCompress Data Compression for MVSCompress Data Compression for Fujitsu
Issue/Introduction
When I try and run CAS9 with REINIT, it fails the load of all the new modules.
I tried taking the library out of the linklist, and adding it back, but it still fails. *TMSRIM14 LOAD FOR MODULE (CTSVTS00) FAILED *TMSRIM14 LOAD FOR MODULE (TMSOSIV ) FAILED *TMSRIM33 TMSRIM: UNSUCCESSFUL REINITIALIZATION CAS9140E - INIT ERROR: CA-1/MVS VER L0E0, INIT ROUTINE RC=0004 WED 19 SEP 18 END STEP 01 CAS9 CAIRIM RC= 00
CAS9 completes, but CA1 init gets a RC=04.
On an upgrade to z/OS 2.3 and after applying the needed maintenance for both Common Services r14.1 and CA-1 r14.0,and attempting a dynamic upgrade of CA-1 from r12.6 to 14.0, a CAS9 REINIT fails to load all the new CA-1 modules.
Environment
z/OS 2.3
Common Services r14.1 with maintenance applied
CA-1 r14.0 with maintenance applied
Resolution
Needed to add specific parameters to the CAIRIM control cards to allow a dynamic upgrade.
Load 14.0 dynamically by executing the CAS9 procedure with the following control statements for CA 1 in CARIMPRM: