What should I do if either message 'CAS9180E - CPU xxxxxx Requires a LMP key to run Prod (yy)' or 'CAS9183A - Product (yy) usage allowed by EKG. Expiration begins in 1 day' appear? (yy is the LMP-Code for TPX which can be: NO, NP, O0, NW, O5 and O3)
book
Article ID: 11442
calendar_today
Updated On:
Products
TPX - Session ManagementVman Session Management for z/OS
Issue/Introduction
What should I do if either of these messages appears for CA TPX:
'CAS9180E - CPU xxxxxx Requires a LMP key to run Prod (yy)'
'CAS9183A - Product (yy) usage allowed by EKG. Expiration begins in 1 day'
(yy is the LMP-Code for TPX which can be: NO, NP, O0, NW, O5 and O3)
Environment
CA TPX for z/OS
Resolution
As soon as valid LMP-Keys are implemented, TPX should be restarted to prevent the messages CAS9180E or CAS9183A from appearing in the TPX Log. Do the following:
Enter the new LMP-Keys into the KEYS member of CA Common Services PPOPTION dataset.
Remove (or comment out) the EKG-Keys in that same member.
Rerun CA-Common Services (normally called CAS9) to put these changes into effect.
Restart TPX.
Additional Information
NOTE: As of May 2017, CA TPX Portfolio Simplification of GA base and option SKUs means that customers should be able to obtain all CA TPX LMP codes as part of their licence.