*TMS001 IEF233A M 07A7,PRIVAT,SL,A1809346,SAVEDSK,TE7.SAF.VSACT10.TTTT 001, *IEF233A M 07A7,PRIVAT,SL,A1809346,SAVEDSK,TE7.SAF.VSACT10.TTTT001, 153 MEDIA2 IECTMS6 07A7,551759,IS APPROVED FOR TRTCH CHANGE IECTMS3 07A7,551759,IS NOT SCRTCH (84) IEC518I SOFTWARE ERRSTAT: REJTMS 07A7,551759,SL,A1809346,SAVEDSK TMS014 IEC502E K 07A7,551759,SL,A1809346,SAVEDSK IEC502E K 07A7,551759,SL,A1809346,SAVEDSK *TMS001 IEC501A M 07A7,PRIVAT,SL,NOCOMP,A1809346,SAVEDSK,TE7.SAF.VSACT 10.TTTT001,MEDIA2 *IEC501A M 07A7,PRIVAT,SL,NOCOMP,A1809346,SAVEDSK,TE7.SAF.VSACT10.TTTT0 01,MEDIA2
Environment
Release: Component: 1
Resolution
84 A request for output required no specific scratch pool, but the volume mounted was assigned to a specific pool.
This means that we need to check the definitions done in the TMOSCR00 and TMONSM00, correct them and then re-start TMSINIT. Running a TMSSTATS with PARM='ALL' we can display all parameters and definitions done and used during the start of TMSINIT. The IBM VTS does not support CA-1 scratch subpooling.