PTXMANB CA/XMANAGER 19.0 PXMQMGCC FAILURE
search cancel

PTXMANB CA/XMANAGER 19.0 PXMQMGCC FAILURE

book

Article ID: 113541

calendar_today

Updated On:

Products

Bind Analyzer for DB2 for z/OS SQL-Ease for DB2 for z/OS SYSVIEW Performance Management Option for DB2 for z/OS Plan Analyzer for DB2 for z/OS Subsystem Analyzer for DB2 for z/OS

Issue/Introduction

We received a dump from the CA XMANAGER task on one of our systems and collection was terminated.
I will send in the dump for your analysis.
The dump title is CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER ASSOCIATES TECHNICAL SUPPORT* Thanks, Ken

Environment

z/os DB2

Cause

Problem: 
PXM3205 DETECTOR COLLECTION TASK STALLED TSKNBR=07 REASON=01 DB2=DB5T 
IEA794I SVC DUMP HAS CAPTURED: 292 
DUMPID=074 REQUESTED BY JOB (PTXMANB ) 
DUMP TITLE=CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT 
COMPUTER ASSOCIATES TECHNICAL SUPPORT* 

Checked Dump 
Dump Title:CA/XMANAGER 19.0 PXMQMGCC FAILURE DIAG/DUMP*CONTACT COMPUTER 
Reviewed 

PXMQCMGCC (rmid SO01875) 
SO01876 and SO01875 both applied 

Resolution

setting existing parameters (Priority, COLLTASKCNT and MAXQ) was able to solve this issue.