After applying CA RS1807 and IPLing, the following message was received:
TSS9048I RDT Synchronization renamed WBEM to USER0002 due to conflict <RDT>
KD94799 points to Top Secret r16 fix RO99650 that causes this issue when applied. This PTF is superseded by SO03596 which is applied. There is no HOLDDATA action for this PTF to notify sites that action is required. Is the text in the article correct for SO03596? Or is there another error introduced?
Here is the HOLDDATA from RO99650 which SO03596 Sup'ed:
1. LLA REFRESH and restart CA Top Secret with TSS,,,REINIT NOTE: the following messages will appear on the mvs console TSS9048I RDT SYNCHRONIZATION RENAMED WBEM USERxxxx DUE TO CONFLICT TSS9045I RDT SYNCHRONIZATION COMPLETE
2. Own the necessary resources via: TSS ADD(dept) WBEM(CIMSERV)
3. Permit access to CIM region control acid via: TSS PERMIT(CIMSERV) WBEM(CIMSERV) ACC(CONTROL)
4. Permit access to the users, for example, CIMUSR, via: TSS PERMIT(CIMUSR) WBEM(CIMSERV) ACC(READ)