What are the specific jobs that CA APCDDS Automated Report Balancing customers must run as a part of their Datacom/AD R11.0 SP4 upgrade?
When you upgrade your Datacom/AD environment to release 11.0 you must run three Datacom jobs that are specific to APCDDS.
They are:
AXPOR01D
AXPOR07D
AXPOR9D.
These jobs are included on the Datacom 11.0 SP4 tape.
With the 10.0 version of DATACOM/AD, the MUF parameters were changed. If you are upgrading from DATACOM/AD release 9.0, the MUF control cards that were supplied with APCDDS 1.1 are no longer valid and can cause errors.
MUF startup options in DBDATIN1(DATACOM), and TKMUFS02(APCDDS) need to include:
MUF ADMUF01,99,YES
ECHO NO
Also, the RESTART option is not allowed with DATACOM/AD 10.0 or higher. Remove step 1 from the CATKMUFS PROC which will eliminate invoking this option.