Upgraded to zVSE 6.1 and unable to get Dynam with CICS TS 2.1 to initialize
search cancel

Upgraded to zVSE 6.1 and unable to get Dynam with CICS TS 2.1 to initialize

book

Article ID: 113330

calendar_today

Updated On:

Products

Dynam for VSE Dynam VSE Option

Issue/Introduction

Trying to make zVSE 6.1 w/ CA-CIS and DYNAM w/ CICS TS 2.1 to run. 

Here are the steps I performed: 

- zVSE 6.1 and CICS/ICCF run ok after the initial installation; 
- The IBM PSP(PTF's...) was installed; 
- zVSE 6.1 and CICS/ICCF run ok after the PSP installation; 
- at this point everything runs ok (POWER and CICS/ICCF) 
- here I began to install CA-CIS and Dynam/VSE 
- all PTF's listed in the CA UPGRAD document were installed (without remarks) 
- created VSAM file initialized CAICUI data set 
- included // DLBL CAICUI,'CAI.CUI.CONTROL.DATASET',,VSAM and // DLBL CAICUIU,'CAI.CUI.CONTROL.DATASET',,VSAM in STDLABUP 
- performed IPL 
- POWER abended for 'PHASE NOT FOUND' at start-up 
- included CA libs in the LIBDEF proc and performed another IPL 
- POWER started-up successfully 
- CICS/ICCF failed to start-up with 0S03I PROGRAM CHECK INTERRUPTION - HEX LOCATION 034FC1E2 - INTERRUPTION CODE 07 - DATA EXCEPTION 

Environment

z/VSE 6.1 

Resolution

This is not a CA Dynam problem. 
The abend is occurring during CICS initialization in CICS phase DFHSIP31. 
At this stage, no CA code is active in CICS. 

 
Customer advised to open a PMR with IBM who determined why CICS was abending.
The problem was in the proc SPLEVEL which had to be edited to change the date format.