SystemEDGE Service does not stay running: WM_SocketCreateServer : Error -1 (2) in bind ( 1028)
search cancel

SystemEDGE Service does not stay running: WM_SocketCreateServer : Error -1 (2) in bind ( 1028)

book

Article ID: 112580

calendar_today

Updated On:

Products

CA Systems Performance for IM (SystemEdge) CA eHealth

Issue/Introduction

  • Unable to start CA SystemEDGE service.
  • The sysedge.log shows the following:
AWM_SocketCreateServer : Error -1 (2) in bind ( 1028).
AWM_SocketCreateServer : Socket was not created.

Environment

Release:
Component: VPMGEN

Cause

  • bind_address parameter was set within the sysedge.cf but it was set to an IP address not defined on the server.

Resolution

  1. Edit sysedge.cf file located under SystemEDGE\config folder and make sure bind_adress is correct value.
  2. Delete SystemEDGE Port# folder located under.


C:\Users\Public\CA\SystemEDGE\Port#
or
/opt/CA/SystemEDGE/config/port#

       
       3.  Start SystemEDGE.